____________________________________________________

ARCH5023/ARCH4333 - ARCHITECTURAL STRUCTURES I

][ STEEL STRUCTURES ][
THE UNIVERSITY OF OKLAHOMA - COLLEGE OF ARCHITECTURE
____________________________________________________



STEEL COLUMNS

ALLOWABLE LOADS


				STEEL COLUMNS
				==============
	   		   	      P&A 312
Column:
======
		compression member
			f = P/A
				f = unit stress
				P = concentrated load
				A = area
		complicated by effects of:	
			buckling
				slenderness main influence
			bending

Column Shapes
===========
		round tube   0
		square tube []
		H-shape wide flange
		heaviest W14x730
		built-up sections
			large columns
			special framing
			[ ] double C
		

Slenderness
========
		see also P&A 218 Chapter 6
		slenderness = L/r  
			L = unbraced length
			r = radius of gyration
 				        -----
				r = V I/A
				r = square root 
					moment of inertia
					dived by the area	
				P&A 167
		modifying factor = K 
			effects of end restraint
		slenderness for building columns
			L/r = 120 max. recommended
		relative slenderness = K x L / r

ALLOWABLE LOADS FOR COLUMNS
==============================
calculation method used for built-up members

PROBLEM: Allowable Loads for Columns

A W 12 x 58 is used as a column
with an unbraced length of 16 ft.
Compute the allowable load.

A. GIVEN:

W 12 x 58 
l = 16 ft
A 36 Steel

B. ASKED

Allowable Load

C. GRAPH

		|
		|
		|	
			l = 16 ft
			W 12 x 58
			A 36

D. SOLUTION

1. No end condition given
===================
	we assume an end condition 
	K = 1
	Table 10.2   P&A 314
2. W 12 x 58
=========
	Table 4.1 P&A 171
	A = 17 sq inch
	r x = 5.28 inch
	r y = 2.51 inch
3. Column is unbraced on both axis
=========================
	it is limited by the lower r value
	for the weaker axis
	r y = 2.51

4. Relative Slenderness
=================
	K l
	----
                 r

	1 (16 ft x 12)
	-----------------
		2.51

              = 76.5
	= 77
	can be rounded of to next higher
	figure in front of decimal point

5. Allowable Unit Stresses for Columns of A36
==================================
	Table 10.1 P&A 316
		for  Kl/r = 77
		Fa = 15.69 ksi
6. Allowable Load 
==============
		P = A x Fa
			A = 17.0 sq inches
				from 	Table 4.1 P&A 171
			Fa = 15.69
				from Table 10.1 P&A 316
		P = 17.0 sq inches x 15.69 k sq inches
		P = 266.7 kips

E. ANSWER

The allowable load for the column is
266. 7 kips
266 kips also correct
267 kips would be incorrect

STEEL COLUMNS RELATED SITES

Steel Columns

Columns





To hear the announcement click on the speaker! sound


LECTURES

To Home Page

Timetable


Prof. Dr. Hermann Gruenwald
(mail comments to: HGRUENWALD@ou.edu)
College of Architecture
The University of Oklahoma

©Dr. Gruenwald 1996, 1997