CONCRETE STRUCTURES

Selection Criteria: ============= column spacing 5' - 100' design loads 40 psf residential 50 psf commercial 100 psf specialty design

One-Way Slab 6'-12' 4" min. thickness thickness = span/30 for floor slabs thickness = span/36 for roof slabs

One-Way Joist Slab 15'-36' 2.5 - 4.5" min. 6" - 20" joist depth min. total depth = span/24

Two-Way Waffle Slab 20' - 48' span 2.5 - 4.5" min. 6" - 20" joist depth min. total depth = span/24 solid heads over columns

Two-Way Slab with Beams 15'-40' span 4" min. depth = slab perimeter/180

Two-Way Flat Slab 15'-40' span 4" min. min. slab depth = span/36 6"-12" typical drop panel min. depth = span/85 drop panel min width = 0.4 span

Two-Way Flat Plate 15'-36' spans 5" min. span/33

Precast Solid Flat Slab 4'-0" wide thickness span 4" 12'-16' 6" 14'-24' 8" 18'-30'

Precast Hollow Core Slab 4'-0" wide thickness span 6" 14'-22' 8" 20'-32' 10" 24'-40' 12" 30'-44'

Precast Single Tee 6', 8', 10', 12' wide thickness span 12" 28'-40' 18" 36'-50' 24" 45'-70' 32" 54'-80' 36" 62'-90' 48" 80'-110'

Precast Double Tee 4', 6', 8', 10', 12' wide thickness span 12" 28'-40' 18" 36'-50' 24" 45'-70' 32" 54'-80' 36" 62'-90' 48" 80'-110'

Precast Rectangular Beam 12" or 16" wide thickness span 20" 18'-30' 28" 22'-40' 36" 26'-50' 44" 30'-56' 52" 34'-70' 60" 42'-80'

Precast L-shaped Beam 12" wide leg 6" wide leg = 1/3 of depth thickness span 20" 18'-30' 28" 22'-40' 36" 26'-50' 44" 30'-56' 52" 34'-70' 60" 42'-80'

Precast Inverted Tee Beam 24" wide legs 6" wide each legs = 1/3 of depth thickness span 20" 18'-30' 28" 22'-40' 36" 26'-50' 44" 30'-56' 52" 34'-70' 60" 42'-80'